Start | Products | Bench Instruments | Electrical Safety Testers | Chroma 19055 Hipot Analyzer 500VA Output Power, Hipot AC 5kV & DC 6kV, Insulation 5kV, 1MΩ~50GΩ
Chroma 19055 Hipot Analyzer 500VA Output Power, Hipot AC 5kV & DC 6kV, Insulation 5kV, 1MΩ~50GΩChroma 19055 Hipot Analyzer 500VA Output Power, Hipot AC 5kV & DC 6kV, Insulation 5kV, 1MΩ~50GΩChroma 19055 Hipot Analyzer 500VA Output Power, Hipot AC 5kV & DC 6kV, Insulation 5kV, 1MΩ~50GΩ
Images
  • Chroma 19055 Hipot Analyzer 500VA Output Power, Hipot AC 5kV & DC 6kV, Insulation 5kV, 1MΩ~50GΩ
  • Chroma 19055 Hipot Analyzer 500VA Output Power, Hipot AC 5kV & DC 6kV, Insulation 5kV, 1MΩ~50GΩ
  • Chroma 19055 Hipot Analyzer 500VA Output Power, Hipot AC 5kV & DC 6kV, Insulation 5kV, 1MΩ~50GΩ

Chroma 19055 Hipot Analyzer 500VA Output Power, Hipot AC 5kV & DC 6kV, Insulation 5kV, 1MΩ~50GΩ

Art. nr: Chroma 19055
6 040 EUR
 
Quantity
 
 
 

Product description

  • 500VA output rating
  • Floating output complies with EN50191
  • Flashover Detection
  • Discharge Level Analysis (DLA)
  • Open Short Check (OSC)
  • High Frequency Contact Check (HFCC)
  • Ground Fault Interrupt
  • Standard RS-232 interface
  • Option GPIB & HANDLER interface
  • Key lock when fail
  • Programmable voltage & test limit
  • Support A190301 8HV Scanning Box

Functions: 

  • Hi-Pot
    • AC 5kV/100mA
    • DC 6kV/25mA
  • Insulation
    • 5kVmax
    • 1MΩ~50GΩ

The Chroma 19055 Series Hipot Analyzer is designed for Hipot test and analysis. It has a maximum output power of 500VA, a maximum AC output of 5kV/100mA, and Floating output for EN50191 requirements. (Please refer to the application notes for more detail information.)

The 19055-C includes ACW/DCW/IR tests, but also has a new measurement technology; Corona Discharge Detection (CDD). In addition, the Breakdown Voltage (BDV)

Analysis can detect faults as follows;

  • Corona discharge Start Voltage (CSV)
  • Flashover Start Voltage (FSV)
  • Breakdown Voltage (BDV)

The Chroma 19055 series also has both High Frequency Contact Check (HFCC) and Open Short Check (OSC) functionality. This increases the test reliability and efficiency significantly through application of the contact check during the Hipot test.

The Chroma 19055 series is equipped with a large LCD screen which is convenient for the user to operate and judge. In addition, a GFI human protection circuit and Floating output design prevents exposing users to electrical hazards.

 

More information

Applications
Motor: The 19055 Series Hipot Analyzers with 500VA output power can be used to test and analyze the high power withstand voltage and leakage current for products like motor stators and rotors with larger parasitic capacitance.
 
Transformer: When a power transformer is
used under normal voltage, Corona discharge from the primary side could cause damage to nearby components. Corona Discharge Detection (CDD), which is a function of 19055-C, can be used to detect this discharge during the design phase for improvement of product quality. Corona Discharge Detection (CDD) can also be used for coil-to-coil or coil-to ground tests to eliminate winding insulation failure due to Corona discharge.
 
High Voltage Capacitor, Photo-coupler & Insulation Material: If any gap, void or impurity is produced during molding of parts in the manufacturing process, the insulation capability of the product can be affected. The Corona Discharge Detection (CDD) function of the 19055-C is able to detect this discharge for improving the final product quality.